WQExplorer

AmmoniaN - 2011-02-24

Estuary/Wetlands

Date Station Result Mean Deviations from Mean

Mass Emissions

Date Station Result Mean Deviations from Mean
2011-03-09 11:50:00 CICF25 - Central Irvine Channel at I-5 0.1 0.123 -0.424
2011-03-09 11:30:00 BARSED - Peters Canyon Wash at Barranca Parkway 0.1 0.122 -0.408
2011-03-09 11:20:00 WYLSED - San Diego Creek at Harvard Avenue 0.1 0.105 -0.25
2011-03-09 11:00:00 SDMF05 - San Diego Creek at Campus Drive 0.1 0.113 -0.33
2011-03-09 10:23:00 SADF01 - Santa Ana Delhi Channel u/s Irvine Avenue 0.1 0.108 -0.24
2011-03-09 10:05:00 CMCG02 - Costa Mesa Channel at Highland 0.1 0.259 -0.434
2011-03-02 14:48:00 ACWF18 - Agua Chinon 0.1 0.156 -0.626
2011-02-24 11:39:00 CMCG02 - Costa Mesa Channel at Highland 0.1 0.259 -0.434
2011-02-24 11:19:00 SDMF05 - San Diego Creek at Campus Drive 0.1 0.113 -0.33
2011-02-24 10:46:00 BARSED - Peters Canyon Wash at Barranca Parkway 0.1 0.122 -0.408

Non Storm Water

Date Station Result Mean Deviations from Mean

Industrial Facilities

Ammonia, Total (as N)

Facility Name Expected Most Recent
Records Mean Std Dev Date Result Deviations from Mean

Ammonia, Unionized (as N)

Facility Name Expected Most Recent
Records Mean Std Dev Date Result Deviations from Mean

Nitrogen, Total (as N)

Facility Name Expected Most Recent
Records Mean Std Dev Date Result Deviations from Mean

Nitrite Plus Nitrate (as N)

Facility Name Expected Most Recent
Records Mean Std Dev Date Result Deviations from Mean

Nitrite, Total (as N)

Facility Name Expected Most Recent
Records Mean Std Dev Date Result Deviations from Mean

Nitrite, Total (as NO2)

Facility Name Expected Most Recent
Records Mean Std Dev Date Result Deviations from Mean

Total Kjeldahl Nitrogen (TKN) (as N)

Facility Name Expected Most Recent
Records Mean Std Dev Date Result Deviations from Mean

Recent Violations

Date Facility Description
2011-03-07 California Square
8616 California Ave, Riverside California 92504
On arrival, staff observed the following: There is limited vegetation growth throughout site. The site's terrain appears to be flat. Perimeter controls are not maintained or non-existent. No additional BMPs are at the site. Off-site sediment tracking or discharge observed. Staff took photos of site.
2011-03-07 California Square
8616 California Ave, Riverside California 92504
The site appears to be in the same condition as noted in the Nov. 2011 inspection, possibly the temp. BMPs are even further degraded. There is limited vegetation growth in Phase 2 of the site. The site's terrain appears to be flat. Perimeter controls are not maintained or non-existent. No additional BMPs are at the site.
2011-03-03 Toll Brothers at Stonebridge
11623 Punta Dulcina and Via Santa Pradera, San Diego California 92131
Rain event during inspection. Observed BMP (gravel bags at storm drain inlet) beginning to fail (sediment & debris) getting through. Storm Drain inlet is at Big Canyon and Punta Dulcina. Requested that Mr Norton correct/improve BMPs at storm drain inlet.
2011-03-02 South Street Apartments
700 E South Street, Anaheim California 92805
Defiecient BMPs throughout site. Liquid concrete dye washed to earthen depression. Concrete washout to soil throughout site. Unprotected inlets on site. SWPPP mising training logs and portions of CGP. SWPPP not certified by QSD.
2011-02-25 Barts Iron Design
25825 Las Vegas Ave, Capistrano Beach California 92624
Per Don Vallandigham: the facility is closed and not operating. The industrial equipment lack BMPs and are improperly stored outside while the facility is awaiting sale.
2011-01-31 Pine Mill
Mill Creek Avenue and Pine Rd, Chino California 91708
See attached inspection report for violation details.
2011-01-26 Midway City Street and Storm Drain Improvements Phase I & II
Bolsa Avenue and Beach Blvd., Midway City California 92655
Many storm drain inlets were found unprotected in the residential area north of Bolsa. A large amount of dirt was found covering Van Buren Street north of Bolsa and two inlets in Bolsa were unprotected. Two stockpiles observed in gutter; one has an inadequate by-pass for gutter flows.
2011-01-19 Agilent Technologies
25200 Commercentre Dr, Lake Forest California 92630
Inlet appears to be fitted with inlet filters; view is obscured by dirt/debris. If filters are present, then the condition is a violation for failure to maintain a treatment control. Contact will investigate to find out if inlet filters are present.
2011-01-19 Agilent Technologies
25200 Commercentre Dr, Lake Forest California 92630
Inlet appears to be fitted with inlet filters; view is obscured by dirt/debris. If filters are present, then the condition is a violation for failure to maintain a treatment control. Contact will investigate to find out if inlet filters are present.
2011-01-18 Mercado Affordable Housing Phase 1
832 South D Street, Perris California 92570
The Phase 2 area has been disturbed and was not stabilized. There are no BMPs present at the Phase 2 site.
2011-01-14 Century Village
13052 Century Blvd, Garden Grove California 92840
Inadequate storm drain inlet protection; vehicle tracking; inadequate perimeter controls; concrete washout; unprotected fluids; outdated SWPPP; missing Risk Level 1 inspection logs.
2011-01-13 Bel Air Swap Meet Overflow Parking
17441 Valley Boulevard, Bloomington California 92316
Inadequate permanent BMP implementation for NOT approval.
2011-01-11 NFCU Riverside
6365 Valley Springs Parkway, Riverside California 92570
Site does not have any BMP protection at the storm drain located in the NW quadrant of the site. Rest of property looks ok. No SWPPP or other documents were present at the site. The site superintendant was not present at the site at the time of inspection.
2011-01-11 NFCU Riverside
6365 Valley Springs Parkway, Riverside California 92570
Site does not have any BMP protection at the storm drain located in the NW quadrant of the site. Rest of property looks ok. No SWPPP or other documents were present at the site. The site superintendant was not present at the site at the time of inspection.
2011-01-11 NFCU Riverside
6365 Valley Springs Parkway, Riverside California 92570
Site does not have any BMP protection at the storm drain located in the NW quadrant of the site. Rest of property looks ok. No SWPPP or other documents were present at the site. The site superintendant was not present at the site at the time of inspection.