Cr - 2015-10-06
Estuary/Wetlands
Date | Station | Result | Mean | Deviations from Mean |
---|
Mass Emissions
Date | Station | Result | Mean | Deviations from Mean |
---|---|---|---|---|
2015-10-06 10:29:00 | EGWC05 - East Garden Grove Wintersburg Channel at Gothard | 1.3 | 5.453 | -0.533 |
2015-10-06 09:49:00 | BCC02 - Bolsa Chica Channel at Westminster | 1.1 | 3.616 | -0.947 |
2015-10-05 10:58:00 | SADF01 - Santa Ana Delhi Channel u/s Irvine Avenue | 2.9 | 7.228 | -0.594 |
2015-10-05 10:20:00 | SDMF05 - San Diego Creek at Campus Drive | 1.9 | 6.265 | -0.468 |
2015-10-05 09:43:00 | EGWC05 - East Garden Grove Wintersburg Channel at Gothard | 6.6 | 5.453 | 0.147 |
2015-10-05 09:09:00 | BCC02 - Bolsa Chica Channel at Westminster | 1.1 | 3.616 | -0.947 |
Non Storm Water
Date | Station | Result | Mean | Deviations from Mean |
---|
Industrial Facilities
Chromium (Total)
Facility Name | Expected | Most Recent | ||||
---|---|---|---|---|---|---|
Records | Mean | Std Dev | Date | Result | Deviations from Mean | |
Abbott Cardiovascular Systems Inc
26531 Ynez Rd, Temecula California 92591 |
3 | 0.009 | 0.01 | 2015-09-15 | 0.02 | 1.106 |
Naval Weapons Station Seal Beach
800 Seal Beach Blvd, Seal Beach California 90740 |
49 | 0.007 | 0.011 | 2015-09-15 | 0.009 | 0.135 |
Chemtronics
1150 W Bradley Ave, El Cajon California 92020 |
16 | 0.013 | 0.017 | 2015-09-15 | 0.01 | -0.166 |
Naval Weapons Station Seal Beach Detachment Fallbrook
700 Ammunition Rd, Fallbrook California 92028 |
5 | 0.004 | 0.004 | 2015-09-15 | 0.005 | 0.114 |
Tamco
12459 B Arrow Rte, Rancho Cucamonga California 91739 |
36 | 0.16 | 0.568 | 2015-09-15 | 0.048 | -0.197 |
Del Mar Fairgrounds Racetrack
2260 Jimmy Durante Blvd, Del Mar California 92014 |
10 | 0.001 | 0 | 2015-09-15 | 0.001 | 0.316 |
San Diego Int Airpor
3225 N Harbor Dr, San Diego California 92101 |
24 | 0.005 | 0.006 | 2015-10-04 | 0.005 | 0.054 |
Pacific Ship Repair
1625 Rigel St, San Diego California 92113 |
2 | 0.003 | 0.002 | 2015-09-15 | 0.004 | 0.707 |
Chromium (VI)
Facility Name | Expected | Most Recent | ||||
---|---|---|---|---|---|---|
Records | Mean | Std Dev | Date | Result | Deviations from Mean | |
Abbott Cardiovascular Systems Inc
26531 Ynez Rd, Temecula California 92591 |
3 | 0.513 | 0.501 | 2015-09-15 | 1 | 0.972 |
San Diego Int Airpor
3225 N Harbor Dr, San Diego California 92101 |
13 | 0.003 | 0.005 | 2015-10-04 | 0 | -0.514 |
Chromium, Dissolved
Facility Name | Expected | Most Recent | ||||
---|---|---|---|---|---|---|
Records | Mean | Std Dev | Date | Result | Deviations from Mean | |
San Diego Int Airpor
3225 N Harbor Dr, San Diego California 92101 |
19 | 0.005 | 0.005 | 2015-10-04 | 0.006 | 0.32 |
Chromium, Total Recoverable
Facility Name | Expected | Most Recent | ||||
---|---|---|---|---|---|---|
Records | Mean | Std Dev | Date | Result | Deviations from Mean |
Recent Violations
Date | Facility | Description |
---|---|---|
2015-10-12 | Playa Del Sol
Del Sol Boulevard and Ocean View Hills Parkway, San Diego California 92154 |
Erosion control BMPs, sediment control BMPs, and perimeter control BMPs are either absent or deficient. There is lack of BMPs to prevent tracking of sediment off site, as well as a lack of BMPs to prevent the transport of sediment offsite by storm water flows. Chris Nichols notified via SEL Email on 01/06/2016 that these deficiencies are violations of the terms and conditions of Pardee Homes enrollment under the Statewide Construction Storm Water Permit, and are subject to enforcement action including monetary penalties. Requested via email that they take immediate corrective actions, as we are in the midst of persistent storms. |
2015-10-02 | Custom Engineering Plastics
8558 Miramar Place, San Diego California 92121 |
Inspection to verify NEC. All industrial manufacturing processes indoors. Some materials stored outside of building most of which are under a structural roofed cover. Some metal shards noted on concrete under structural cover- housekeeping issue. Some rusty metal parts are outdoors on a pallet covered with a poly tarp that is torn. Requested corrective action on the housekeeping (Sweeping) and replacement of the tarp that is covering the metal machine parts. Recommended storm drain inlet protection and rain gutters for outdoor roofed structural cover. |
2015-09-15 | Murrieta Creek
Murrieta Creek , Temecula California 92590 |
Observed significant flow through the project area as it is located in Murrieta Creek. Upsteam flow into the project area appeared to be much less turbid than within and downstream of the project. Observed a complete lack of erosion controls on slopes that appeared to be inactive or could be scheduled to be inactive. Observed a complete lack of erosion controls (runoff control and soil stabilization in areas that appeared to be active, as required for Risk Level 2 sites. Observed lack of linear sediment controls along face and grade breaks of exposed slopes, as required for Risk Level 2 site. Observed inadequate implementation of runon and runoff controls. Observed inadequate stockpile management BMPs. |
2015-09-15 | Murrieta Creek
Murrieta Creek , Temecula California 92590 |
Observed discharges of sediment and sediment-laden water to receiving water due to inadequate implementation of erosion, sediment, runon and runoff control BMPs. |
2015-09-15 | Murrieta Creek
Murrieta Creek , Temecula California 92590 |
Slopes still lacked evidence of erosion control BMPs, but site representative emailed after inspection that BFM was being applied. No run-on controls observed, no linear sediment controls on slopes observed, and no controls to manage runoff within the site observed. |
2015-09-15 | Murrieta Creek
Murrieta Creek , Temecula California 92590 |
Photos show inadequate implementation of sediment control, erosion control, and runon/runoff control BMPs. She photos attached to staff enforcement email. |
2015-09-03 | TRA Medical
1005 Ortega Way, Placentia California 92870 |
non-storm water discharge observed exiting facility on the west side to the parking lot to concrete swale, discharging into storm drain inlet. |
2015-08-31 | SPL Waterhousings Inc
4745 Mission Bay Dr Ste B, San Diego California 92109 |
No Exposure Certification (NEC) inspection by Lucas Lima who made some observations of concern. Housekeeping BMPs (Best Management Practices) outside of the building are deficient. The BMP deficiencies are: metal shards on the ground outside as well as a pile of dirt that does not have any containment, and both are exposed to storm water. SEL email was sent to discharger by W. Ghoram on 10/22/2015 advising that discharges of storm water commingling with/containing pollutants/wastes (ie: metal shards, soil, etc..) to surface waters, directly or via storm drains, are violations and that based on the inspection observations the facility does not meet NEC criteria. Requested that the discharger take corrective actions on the BMP deficiencies and email photos of the corrections no later than October 30, 2015. |