Date Station Result Mean Deviations from Mean
2015-09-24 12:57:00 HUNWAR - Huntington Harbour at Warner Avenue 1.1 0.777 1.846
2015-09-24 12:08:00 HUNCRB - Huntington Harbour in Christiana Bay 1.2 0.808 1.17
2015-09-24 11:41:00 TBTMAR - Talbert Marsh 0.9 0.611 1.354
2015-09-24 10:15:00 TGDC05 - Bolsa Bay d/s E. Garden Grove Wintersburg Ch. 0.79 0.858 -0.248
2015-09-24 09:37:00 HUNBCC - Huntington Harbour d/s of Bolsa Chica Ch. 0.62 0.821 -0.596
2015-09-24 09:10:00 BBOLR - Bolsa Bay at observation pier 2 1.391 0.758

Mass Emissions

Date Station Result Mean Deviations from Mean
2015-09-29 12:50:00 CMCG02 - Costa Mesa Channel at Highland 7 3.496 1.028
2015-09-29 12:25:00 SADF01 - Santa Ana Delhi Channel u/s Irvine Avenue 4.6 2.956 0.905
2015-09-29 11:57:00 SDMF05 - San Diego Creek at Campus Drive 4.4 2.893 1.412
2015-09-29 10:37:00 WYLSED - San Diego Creek at Harvard Avenue 1.4 2.904 -1.109
2015-09-29 10:27:00 BARSED - Peters Canyon Wash at Barranca Parkway 1.5 2.215 -0.668
2015-09-29 09:59:00 CICF25 - Central Irvine Channel at I-5 1.2 3.355 -1.774
2015-09-23 11:00:00 CARB01 - Carbon Creek at Bloomfield 2.5 1.957 1.039
2015-09-23 10:41:00 EGWC05 - East Garden Grove Wintersburg Channel at Gothard 5.5 3.4 1.543
2015-09-23 10:08:00 BCC02 - Bolsa Chica Channel at Westminster 2.9 1.902 1.354
2015-09-23 10:00:00 CCBA01 - Coyote Creek d/s Artesia Blvd. 2.9 2.444 0.574

Non Storm Water

Date Station Result Mean Deviations from Mean

Industrial Facilities

Nickel, Dissolved

Facility Name Expected Most Recent
Records Mean Std Dev Date Result Deviations from Mean
San Diego Int Airpor
3225 N Harbor Dr, San Diego California 92101
19 0.005 0.005 2015-10-04 0.008 0.485

Nickel, Total

Facility Name Expected Most Recent
Records Mean Std Dev Date Result Deviations from Mean
Forged Metals
10685 Beech Avenue, Fontana California 92337
36 0.052 0.065 2015-10-04 0.048 -0.05
2015-09-15 0.073 0.33
Capistrano USD Aliso Viejo
2B Liberty, Aliso Viejo California 92656
4 0.031 0.022 2015-09-15 0.007 -1.075
Chemtronics
1150 W Bradley Ave, El Cajon California 92020
18 0.034 0.047 2015-09-15 0.049 0.315
San Marcos Unified Sch Dist
215 Mata Way, San Marcos California 92069
7 0.018 0.016 2015-09-15 0.007 -0.686
Markland Manufacturing Inc
1111 E Mcfadden Ave, Santa Ana California 92705
21 1.036 2.559 2015-09-15 0.049 -0.386
2015-09-08 0.151 -0.346
Naval Weapons Station Seal Beach
800 Seal Beach Blvd, Seal Beach California 90740
51 0.017 0.048 2015-09-15 0.005 -0.242
Naval Weapons Station Seal Beach Detachment Fallbrook
700 Ammunition Rd, Fallbrook California 92028
5 0.004 0.004 2015-09-15 0.004 0.096
Brasstech Inc
2001 Carnegie Ave, Santa Ana California 92705
18 0.017 0.009 2015-09-15 0.016 -0.149
2015-09-10 0.011 -0.666
San Ysidro Sch Dist
4350 Otay Mesa Rd, San Ysidro California 92173
3 0.005 0.009 2015-09-15 0 -0.588
Del Mar Fairgrounds Racetrack
2260 Jimmy Durante Blvd, Del Mar California 92014
10 0.002 0.001 2015-09-15 0.002 0.316
San Diego Int Airpor
3225 N Harbor Dr, San Diego California 92101
21 0.006 0.006 2015-10-04 0.009 0.508
Fallbrook UESD Trans
825 Winterhaven Rd, Fallbrook California 92028
3 0.004 0.006 2015-09-15 0.011 1.155
Pacific Ship Repair
1625 Rigel St, San Diego California 92113
2 0.012 0.001 2015-09-15 0.011 -0.707
Valley Ctr Pauma U S D
28751 Cole Grade Rd, Valley Center California 92082
4 0.026 0.027 2015-10-05 0.005 -0.776
Jamul Dulzura Usd Bus Maint Fac
14581 Lyons Valley Rd, Jamul California 91935
3 0.017 0.029 2015-09-15 0 -0.577
Brasstech Inc
311 E Alton Ave, Santa Ana California 92707
29 0.046 0.057 2015-09-15 0.013 -0.578
2015-09-10 0.029 -0.297
Brasstech Inc
3220 S Standard Ave, Santa Ana California 92705
22 2.957 7.254 2015-09-15 11.323 1.153
2015-09-10 3.482 0.072
Oceanside Unified School District
2070 Mission Ave, Oceanside California 92054
4 0.03 0.023 2015-09-15 0.011 -0.859
Poway USD Transportation
13626 Twin Peaks Rd, Poway California 92064
5 0.033 0.023 2015-09-15 0.009 -1.06
Ramona USD
720 9th St, Ramona California 92065
3 0.021 0.025 2015-09-15 0.008 -0.517
Safety Kleen Corp
7979 Palm Ave, Highland California 92346
3 0.031 0.016 2015-09-15 0.013 -1.155
Warner Unified School District
30951 Hwy 79, Warner Springs California 92086
1 0 0 2015-09-15 0 0
Escondido Hs Student Trans
1789 N Broadway, Escondido California 92026
4 0.025 0.029 2015-09-15 0 -0.866
Cajon Valley Union Sch Dist
721 E Park Ave, El Cajon California 92020
3 0.017 0.029 2015-09-15 0 -0.577
Acushnet Co
2819 Loker Ave E, Carlsbad California 92010
13 0.086 0.131 2015-09-15 0.264 1.358
Santee Sch Dist Bus Mainten Fac
9880 Riverwalk Dr, Santee California 92071
2 0.025 0.035 2015-09-15 0 -0.707

Nickel, Total Recoverable

Facility Name Expected Most Recent
Records Mean Std Dev Date Result Deviations from Mean

Recent Violations

Date Facility Description
2015-10-02 Custom Engineering Plastics
8558 Miramar Place, San Diego California 92121
Inspection to verify NEC. All industrial manufacturing processes indoors. Some materials stored outside of building most of which are under a structural roofed cover. Some metal shards noted on concrete under structural cover- housekeeping issue. Some rusty metal parts are outdoors on a pallet covered with a poly tarp that is torn. Requested corrective action on the housekeeping (Sweeping) and replacement of the tarp that is covering the metal machine parts. Recommended storm drain inlet protection and rain gutters for outdoor roofed structural cover.
2015-09-15 Murrieta Creek
Murrieta Creek , Temecula California 92590
Slopes still lacked evidence of erosion control BMPs, but site representative emailed after inspection that BFM was being applied. No run-on controls observed, no linear sediment controls on slopes observed, and no controls to manage runoff within the site observed.
2015-09-15 Murrieta Creek
Murrieta Creek , Temecula California 92590
Observed significant flow through the project area as it is located in Murrieta Creek. Upsteam flow into the project area appeared to be much less turbid than within and downstream of the project. Observed a complete lack of erosion controls on slopes that appeared to be inactive or could be scheduled to be inactive. Observed a complete lack of erosion controls (runoff control and soil stabilization in areas that appeared to be active, as required for Risk Level 2 sites. Observed lack of linear sediment controls along face and grade breaks of exposed slopes, as required for Risk Level 2 site. Observed inadequate implementation of runon and runoff controls. Observed inadequate stockpile management BMPs.
2015-09-15 Murrieta Creek
Murrieta Creek , Temecula California 92590
Photos show inadequate implementation of sediment control, erosion control, and runon/runoff control BMPs. She photos attached to staff enforcement email.
2015-09-15 Murrieta Creek
Murrieta Creek , Temecula California 92590
Observed discharges of sediment and sediment-laden water to receiving water due to inadequate implementation of erosion, sediment, runon and runoff control BMPs.
2015-09-03 TRA Medical
1005 Ortega Way, Placentia California 92870
non-storm water discharge observed exiting facility on the west side to the parking lot to concrete swale, discharging into storm drain inlet.
2015-08-31 SPL Waterhousings Inc
4745 Mission Bay Dr Ste B, San Diego California 92109
No Exposure Certification (NEC) inspection by Lucas Lima who made some observations of concern. Housekeeping BMPs (Best Management Practices) outside of the building are deficient. The BMP deficiencies are: metal shards on the ground outside as well as a pile of dirt that does not have any containment, and both are exposed to storm water. SEL email was sent to discharger by W. Ghoram on 10/22/2015 advising that discharges of storm water commingling with/containing pollutants/wastes (ie: metal shards, soil, etc..) to surface waters, directly or via storm drains, are violations and that based on the inspection observations the facility does not meet NEC criteria. Requested that the discharger take corrective actions on the BMP deficiencies and email photos of the corrections no later than October 30, 2015.
2015-08-19 HVAC Exchange
2675 Faivre St, Chula Vista California 91911
Facility lacks housekeeping BMPs, structural BMPs, secondary containment BMPs and perimeter controls. A number of violations were noted during the inspection, including discharges of wastes offsite: -Failure to maintain a copy of the facility SWPPP (Storm Water Pollution Prevention Plan) onsite. -Failure to implement the SWPPP and failure to conduct employee training on the SWPPP. -Failure to implement housekeeping BMPs, structural BMPs, secondary containment BMPs, and perimeter controls. -Insulation and other materials/pollutants discharged offsite. -Exposure of metals, insulation, and other pollutants from appliances, that are on the ground and exposed to storm water at various locations at the site. -Trash & debris on ground around dumpster containing soil at the southeast side of the facility. -Contaminated soil discharged on site and off site. -Open buckets and drums of materials and wastes. -Spilled oil on the ground (concrete) at various locations on the site. -Oily ponded water at various locations on site. -Exposed broken appliances and appliance components at various locations on site. -Rusty metal parts and hardware stored outside, exposed to storm water. The materials and wastes exposed to storm water include household appliances, radiators, foam insulation, metals, refrigerants, mercury switches, circuit boards, wiring, nuts & bolts, oil, hydraulic fluid.