WQExplorer

Sb - 2012-09-11

Estuary/Wetlands

Date Station Result Mean Deviations from Mean
2012-09-19 11:54:00 HUNWAR - Huntington Harbour at Warner Avenue 0.32 0.281 0.79
2012-09-19 11:51:00 TBTMAR - Talbert Marsh 0.24 0.278 -1.232
2012-09-19 10:50:00 HUNCRB - Huntington Harbour in Christiana Bay 0.27 0.271 -0.026
2012-09-19 10:27:00 BBOLR - Bolsa Bay at observation pier 0.4 0.341 0.979
2012-09-19 09:38:00 HUNBCC - Huntington Harbour d/s of Bolsa Chica Ch. 0.27 0.287 -0.264
2012-09-19 09:12:00 TGDC05 - Bolsa Bay d/s E. Garden Grove Wintersburg Ch. 0.34 0.316 0.731
2012-09-13 11:02:00 LNBTUB - Lower Newport Bay at TUB 0.24 0.255 -0.298
2012-09-13 09:55:00 LNBHIR - Lower Newport Bay at Harbor Island Reach 0.22 0.246 -0.715
2012-09-13 08:55:00 UNBCHB - Upper Newport Bay at Coast Highway 0.26 0.266 -0.108
2012-09-11 12:04:00 UNBNSB - Upper Newport Bay at Northstar Beach 0.3 0.283 0.278
2012-09-11 10:40:00 UNBSDC - Upper Newport Bay - Unit II Basin 0.3 0.299 0.009
2012-09-11 09:35:00 UNBJAM - Upper Newport Bay - Unit I Basin 0.32 0.349 -0.366

Mass Emissions

Date Station Result Mean Deviations from Mean

Non Storm Water

Date Station Result Mean Deviations from Mean

Industrial Facilities

Antimony, Dissolved

Facility Name Expected Most Recent
Records Mean Std Dev Date Result Deviations from Mean

Antimony, Total

Facility Name Expected Most Recent
Records Mean Std Dev Date Result Deviations from Mean

Recent Violations

Date Facility Description
2012-09-21 Cardiff Collection
1264 Lake Drive, Encinitas California 92024
Inadequate implementation of good housekeeping, erosion controls for active areas, and perimeter sediment and runoff/runon controls observed during inspection. Inadequate implementation of erosion control BMPs resulted in discharge of turbid storm water from the site, reported in ad-hoc report.
2012-09-20 Iowa Ave Grade Separation
690 Iowa Avenue, Riverside California 92507
Inadequate BMP implementation. The limited BMPs at the site were inadequate and sediment discharge was observed. Sediment laden water flowed from the Citrus and the RR tracks west to East La Cadena Drive and then South to almost Oxford St. where there was a storm drain. Sedement laden storm water flowed into that catch basin. In addition, sedement laden storm water flowed from the site into the storm drain on the corner of Palmyrita Ave. and Iowa Ave. Also, sediment laden storm water flowed into the storm drain on E. Citrus Street near the RR tracks (see photos).
2012-09-20 Iowa Ave Grade Separation
690 Iowa Avenue, Riverside California 92507
Straw waddles were on some of the the site slopes, however, they were not keyed into the ground. There was also a limited amount of Silt Fence at two primary locations at the site.
2012-09-18 Holliday Rock Chino 18
5150 Schaefer Ave, Chino California 91710
The northwest gate did not have any BMPs at the discharge point or around the soil/gravel stockpiles near-by that would flow to the northwest discharge point.
2012-09-14 Harmony Grove Village
2900 Harmony Grove Road, San Diego California 92029
Inadequate implementation of erosion and sediment controls for a Risk Level 2 site. Inadequate implementation of good site management "housekeeping" BMPs and non-storm water management. Inadequate maintenance of erosion and sediment control BMPs.
2012-09-14 Harmony Grove Village
2900 Harmony Grove Road, San Diego California 92029
Observed several areas where erosion control and sediment control BMPs had been implemented but not adequately maintained and repaired to remain effective. In these areas evidence of erosion (i.e. rills) and sediment transport, likely from January 2016 or earlier storms, was observed.
2012-09-14 Harmony Grove Village
2900 Harmony Grove Road, San Diego California 92029
Observed discharges of non-storm water runoff to storm drain inlets from over-irrigation. Irrigation water appears to be recycled water. Site appears to drain to two large detention basins, but basin outlets do not appear to have risers that prevent discharges to Escondido Creek. Discharges from over-irrigation and discharges of recycled water to Escondido Creek are not authorized non-storm water discharges in the San Diego Region under the CGP.
2012-09-14 Harmony Grove Village
2900 Harmony Grove Road, San Diego California 92029
Discharge of sediment to a receiving water channel due to lack of adequate erosion and sediment control BMPs.
2012-09-12 Language Academy
4961 64th St, San Diego California 92115
Routine inspection during rain event. Inspector observed sediment laden storm water discharging from the site into the gutter via the sloped driveway entrance which had an inadequate quantity of 3 inch minus rock and lacking a berm. Requested that discharger immediately install a decomposed granite (DG) 3 foot wide berm and 1 foot high in a curved (speed bump) shape to allow for ingress/egress of trucks & other vehicles. Also requested discharger to install more 3 inch minus rock behind the DG berm to prevent tracking offsite. Mr. Robbins said he ordered 25 tons of 3 inch minus for delivery on 12/19/2012 by Hanson Aggregates. Photos via email to verify - pending.
2012-09-10 Edinger Storm Channel, Phase 2
Edinger, Huntington Beach California 92647
Observed evidence of past disposal of cement waste on to the ground: small piles of cured cement surrounded by pale staining. Observed open paint can containing unknown liquid upright in channel work area: worker removed when brought to their attention.
2012-08-29 Campanula Way Apartments
31901 Campanula Way, Temecula California 92592
Deficient housekeeping, erosion, and sediment control BMPs. QSP inspections on monthly not weekly basis.
2012-08-17 Andres Technical Plating Inc
1055 Ortega Way, Placentia California 92870
general housekeeping issues, black residue observed on the roof
2012-08-15 Butterfield Residence
21485 Highway 243, Idyllwild California 92220
No post-construction BMPs observed
2012-08-15 Kelvin Apartments
2852 Kelvin Avenue, Irvine California 92614
Deficient BMP Implementation.
2012-08-15 Flavours Inc
24845 Corbit Place, Yorba Linda California 92887
Discharge of washdown almond milk from north truck well. Discharge documented by OCPW.
2012-08-15 Butterfield Residence
21485 Highway 243, Idyllwild California 92220
Lack of effective BMPs after being warned once.
2012-08-03 Klein Metals and Recycling
8740 Miramar Place, San Diego California 92121
Drive by inspection while in the vicinity for another inspection. Metal shards on the ground inside the gate and outside the gate on the ground (dirt area and pavement). Poor Housekeeping. I advised the employee that was working there to clean up the metal shards. He agreed to do so. Left my business card with the employee to give to Mr. Klein.
2012-07-30 Accurate Metal Solutions Anaheim LLC
2100 E Orangewood Ave, Anaheim California 92806
Neglected trash and debris found underneath the trash compactor and by ribbon gutter and small sinkhole out back by the laser area. Abandoned sorbent found around compressor where boom have weathered and broken open. Rain gutter for building adjacent to the compressor pad needs to be repaired; allows rain water to flow onto the oily pad area.
2012-07-30 Accurate Metal Solutions Anaheim LLC
2100 E Orangewood Ave, Anaheim California 92806
Chiller water is leaking from the unit through a removed screen and an overflow pipe that is plumbed to discharge to the ground.
2012-07-30 Accurate Metal Solutions Anaheim LLC
2100 E Orangewood Ave, Anaheim California 92806
Sinkhole continues to accumulate weathered trash and compactor is not being fully maintained. Employees are not routinely cleaning out the debris bin that captures material on the ram's return stroke; bin is packed.