WQExplorer

Sb - 2015-09-24

Estuary/Wetlands

Date Station Result Mean Deviations from Mean
2015-09-24 12:57:00 HUNWAR - Huntington Harbour at Warner Avenue 0.28 0.281 -0.029
2015-09-24 12:08:00 HUNCRB - Huntington Harbour in Christiana Bay 0.35 0.271 1.416
2015-09-24 11:41:00 TBTMAR - Talbert Marsh 0.27 0.278 -0.259
2015-09-24 09:37:00 HUNBCC - Huntington Harbour d/s of Bolsa Chica Ch. 0.31 0.287 0.352
2015-09-24 09:10:00 BBOLR - Bolsa Bay at observation pier 0.33 0.341 -0.183

Mass Emissions

Date Station Result Mean Deviations from Mean

Non Storm Water

Date Station Result Mean Deviations from Mean

Industrial Facilities

Antimony, Dissolved

Facility Name Expected Most Recent
Records Mean Std Dev Date Result Deviations from Mean

Antimony, Total

Facility Name Expected Most Recent
Records Mean Std Dev Date Result Deviations from Mean
Del Mar Fairgrounds Racetrack
2260 Jimmy Durante Blvd, Del Mar California 92014
12 0.01 0.013 2015-09-15 0.022 1.021

Recent Violations

Date Facility Description
2015-10-02 Custom Engineering Plastics
8558 Miramar Place, San Diego California 92121
Inspection to verify NEC. All industrial manufacturing processes indoors. Some materials stored outside of building most of which are under a structural roofed cover. Some metal shards noted on concrete under structural cover- housekeeping issue. Some rusty metal parts are outdoors on a pallet covered with a poly tarp that is torn. Requested corrective action on the housekeeping (Sweeping) and replacement of the tarp that is covering the metal machine parts. Recommended storm drain inlet protection and rain gutters for outdoor roofed structural cover.
2015-09-15 Murrieta Creek
Murrieta Creek , Temecula California 92590
Slopes still lacked evidence of erosion control BMPs, but site representative emailed after inspection that BFM was being applied. No run-on controls observed, no linear sediment controls on slopes observed, and no controls to manage runoff within the site observed.
2015-09-15 Murrieta Creek
Murrieta Creek , Temecula California 92590
Observed significant flow through the project area as it is located in Murrieta Creek. Upsteam flow into the project area appeared to be much less turbid than within and downstream of the project. Observed a complete lack of erosion controls on slopes that appeared to be inactive or could be scheduled to be inactive. Observed a complete lack of erosion controls (runoff control and soil stabilization in areas that appeared to be active, as required for Risk Level 2 sites. Observed lack of linear sediment controls along face and grade breaks of exposed slopes, as required for Risk Level 2 site. Observed inadequate implementation of runon and runoff controls. Observed inadequate stockpile management BMPs.
2015-09-15 Murrieta Creek
Murrieta Creek , Temecula California 92590
Photos show inadequate implementation of sediment control, erosion control, and runon/runoff control BMPs. She photos attached to staff enforcement email.
2015-09-15 Murrieta Creek
Murrieta Creek , Temecula California 92590
Observed discharges of sediment and sediment-laden water to receiving water due to inadequate implementation of erosion, sediment, runon and runoff control BMPs.
2015-09-03 TRA Medical
1005 Ortega Way, Placentia California 92870
non-storm water discharge observed exiting facility on the west side to the parking lot to concrete swale, discharging into storm drain inlet.
2015-08-31 SPL Waterhousings Inc
4745 Mission Bay Dr Ste B, San Diego California 92109
No Exposure Certification (NEC) inspection by Lucas Lima who made some observations of concern. Housekeeping BMPs (Best Management Practices) outside of the building are deficient. The BMP deficiencies are: metal shards on the ground outside as well as a pile of dirt that does not have any containment, and both are exposed to storm water. SEL email was sent to discharger by W. Ghoram on 10/22/2015 advising that discharges of storm water commingling with/containing pollutants/wastes (ie: metal shards, soil, etc..) to surface waters, directly or via storm drains, are violations and that based on the inspection observations the facility does not meet NEC criteria. Requested that the discharger take corrective actions on the BMP deficiencies and email photos of the corrections no later than October 30, 2015.
2015-08-19 HVAC Exchange
2675 Faivre St, Chula Vista California 91911
Facility lacks housekeeping BMPs, structural BMPs, secondary containment BMPs and perimeter controls. A number of violations were noted during the inspection, including discharges of wastes offsite: -Failure to maintain a copy of the facility SWPPP (Storm Water Pollution Prevention Plan) onsite. -Failure to implement the SWPPP and failure to conduct employee training on the SWPPP. -Failure to implement housekeeping BMPs, structural BMPs, secondary containment BMPs, and perimeter controls. -Insulation and other materials/pollutants discharged offsite. -Exposure of metals, insulation, and other pollutants from appliances, that are on the ground and exposed to storm water at various locations at the site. -Trash & debris on ground around dumpster containing soil at the southeast side of the facility. -Contaminated soil discharged on site and off site. -Open buckets and drums of materials and wastes. -Spilled oil on the ground (concrete) at various locations on the site. -Oily ponded water at various locations on site. -Exposed broken appliances and appliance components at various locations on site. -Rusty metal parts and hardware stored outside, exposed to storm water. The materials and wastes exposed to storm water include household appliances, radiators, foam insulation, metals, refrigerants, mercury switches, circuit boards, wiring, nuts & bolts, oil, hydraulic fluid.