WQExplorer

Se - 2014-09-17

Estuary/Wetlands

Date Station Result Mean Deviations from Mean
2014-09-17 11:40:00 TBTMAR - Talbert Marsh 0.5 0.233 1.374
2014-09-17 10:50:00 TGDC05 - Bolsa Bay d/s E. Garden Grove Wintersburg Ch. 0.5 0.241 1.314
2014-09-17 08:50:00 BBOLR - Bolsa Bay at observation pier 0.1 0.242 -0.721
2014-09-16 11:55:00 HUNWAR - Huntington Harbour at Warner Avenue 0.1 0.25 -0.75
2014-09-16 10:45:00 HUNCRB - Huntington Harbour in Christiana Bay 0.1 0.26 -0.789
2014-09-16 09:13:00 HUNBCC - Huntington Harbour d/s of Bolsa Chica Ch. 0.1 0.25 -0.75

Mass Emissions

Date Station Result Mean Deviations from Mean

Non Storm Water

Date Station Result Mean Deviations from Mean

Industrial Facilities

Selenium, Dissolved

Facility Name Expected Most Recent
Records Mean Std Dev Date Result Deviations from Mean

Selenium, Total

Facility Name Expected Most Recent
Records Mean Std Dev Date Result Deviations from Mean

Selenium, Total Recoverable

Facility Name Expected Most Recent
Records Mean Std Dev Date Result Deviations from Mean

Recent Violations

Date Facility Description
2014-09-24 Hampshire at College Park
NW Corner of Satterfield Way and Mountain Ave, Chino California 91710
BMPS were removed along one street to facilitate the removal of dirt placed on the street. The area will be swept on Friday and the BMPS re-established on Friday prior to the next rain event.
2014-09-19 Innovative Hearth Products
2701 S Harbor Blvd, Santa Ana California 92704
Lack of secondary containment, deficient BMP implementation in casting area, general housekeeping issues
2014-09-16 Village of Terrassa
Foothill Parkway, Corona California 92881
Perimeter controls do not appear to be robust because it is not clear where the runoff will occur. There is silt fence and sand bags, but wherever the flow concentrates may or may not have an adequate perimeter control and it is unclear where that will be. Next there was a sediment basin that site staff stated would be used for sediment control. But the sediment basin had no stand pipe or emergency spillway and the SWPPP uploaded to SMARTS stated nothing about using the required CASQA sediment basin design.
2014-09-03 UCHS Athletic Facilities Upgrade
6949 Genesee Avenue San diego CA 92122, San Diego California 92122
1. Evidence of an unauthorized discharge of sediment leaving the site from prior rain event 2. And, most importantly, the slope along Genessee Avenue was cleared and grubbed months ago at the beginning of project construction, and has still not been stabilized with erosion or sediment controls, even though it clearly appears to be inactive. There is further evidence of rilling and discharges of sediment from that slope to Genesee.
2014-09-03 UCHS Athletic Facilities Upgrade
6949 Genesee Avenue San diego CA 92122, San Diego California 92122
2. Inadequate perimeter control 3. Tracking 4. And, most importantly, the slope along Genessee Avenue was cleared and grubbed months ago at the beginning of project construction, and has still not been stabilized with erosion or sediment controls, even though it clearly appears to be inactive. There is further evidence of rilling and discharges of sediment from that slope to Genesee.
2014-08-26 San Diego Marriott Marquis & Marina New Marriot Hall
333 W Harbor Dr, San Diego California 92101
San Diego Unified Port District reported a water main break at the construction site that resulted in an unauthorized non-storm water discharge, including sediment and sediment laden water, from the site to San Diego Bay and the MS4.
2014-08-26 San Diego Marriott Marquis & Marina New Marriot Hall
333 W Harbor Dr, San Diego California 92101
Stockpile management, erosion control, sediment control, and run-on/runoff control BMP deficiencies identified.
2014-08-21 College Park PA 17
Edison Ave & Mountain Ave, Chino California 91710
Housekeeping was inadequate two days after the rain event. In addition, circumventing the BMP by pulling it back discharging sediment laden water is a violation of Section VI.C. of Order 2014-0057-DWQ, and Attachment C Section A.1.b. of Order 2014-0057-DWQ.
2014-08-21 College Park PA 17
Edison Ave & Mountain Ave, Chino California 91710
Fine grain sediment located around the storm drain at the West side of the intersection of Rutgers and Diablo. There were two gravel bags added but insufficient for the size of soil particles observed around the drain. On the east side of Diablo and Rutgers the BMP was too short for the length of opening so one gravel bag on each end was added. In addition, insufficient BMPs were placed at the drain inlet at Diablo and Haverford.
2014-08-07 OC Fair & Event Center
88 Fair Dr, Costa Mesa California 92626
Inlet filter missing filter fabric; sedimentation basin not maintained; open drains on secondary containment for fuel tank.